A unique artwork drawn by the system from this transformer’s own data: its rating, phases, status and place. No two Patras carry the same portrait.
Field photographSealed at capture
The real photograph of this transformer appears here. Full view, as taken in the field.
16-11-2026 · 10:42 IST26.8xx°N 80.9xx°E · ±3 m
What the photograph showsREAD BY AICONFIRMED · JE
Pole-mounted unit on a double-pole structure beside a lane. Bushings and arresters intact; oil level normal. Light oil staining below the drain valve. LT box closed, earthing connected. Vegetation within 1 m of the left pole.
Engineering drawing · General arrangementDimensions indicative for a 250 kVA unit · verify on site
Location · GIS and GPSCaptured in the field · VERIFIED · SDO
Coordinates
26.8xx° N, 80.9xx° E
Accuracy
± 3 m (GNSS, 14 satellites)
DigiPIN
[generated from coordinates]
Locality
[Mohalla / ward], Lucknow
Utility
Madhyanchal Vidyut Vitran Nigam Ltd (MVVNL)
Zone · circle
[Zone] · [Circle]
Division · sub-division
[Division] · [Sub-division]
33/11 kV substation
[Substation]
11 kV feeder
[Feeder]
Area served
≈ 180 connections · 3 lanes
Chai Kreative and Advisory Private Limited · CIN U74999DL2017PTC314648 · www.chaikreativeadvisory.com · Idea and concept: Kewal Kapoor Sample record for illustration; it does not describe a real asset. Power Pehchaan is not a government application. Verify the live record by QR.
FRONT · 1 / 4
SAMPLE · ILLUSTRATIVE RECORD
PP-UP-SMP-000001-7Life record · जीवन वृत्त
The life of a transformer
WATCH
Nameplate and specificationsSource · status
Rating
250 kVA
AIVERIFIED
Voltage ratio
11 / 0.433 kV
VERIFIED
Phases · vector group · %Z
3 · Dyn11 · 4.5%
VERIFIED
Cooling · core
ONAN · CRGO
REGISTER
Winding
Copper
DECLARED
Efficiency · losses
Level [ ] · NL [ ] W · LL [ ] W
DECLARED
Oil · total weight
≈ 260 L · ≈ 1 150 kg
MAKER
Make · serial
[Manufacturer] · [Serial]
AIVERIFIED
Manufactured · installed
03/2014 · 07/2014
REGISTER
Warranty
Expired 07/2019
REGISTER
Risk and recommended actionConfidence: high
62of 100
Overloaded on 38 days this summer (peak 112%)
Oil test (BDV) overdue by 2 months
2 failures in the last 5 years
Light oil staining seen in the latest photograph
Recommended: oil test this week · inspect drain valve · review for 400 kVA before summer 2027. Assigned to: JE, [sub-division] · due 21-11-2026
Load · last 12 monthsPeak % of rating · DT meter
DecMarMayJulSepNov
Life timelineEvery event, in order
2014
Installed · 250 kVA
2017
Oil filtered
2019
Warranty ended
2022
Failure · LT bushing
2024
Failure · overload
2025
BDV test · 38 kV
2026
Verified · v4
Maintenance cardLast done → next due
Item
Last
Next
Status
Oil test (BDV)
09/2025
09/2026
OVERDUE
Oil level and leaks
11/2026
02/2027
OK
Silica-gel breather
06/2026
12/2026
DUE SOON
Insulation resistance
09/2025
09/2026
OVERDUE
Earth resistance
03/2026
03/2027
OK
Bushings, terminals
11/2026
05/2027
OK
Pre-summer readiness
04/2026
03/2027
PLANNED
Verification and responsibilityWho stands behind this record
Field capture
Lineman · 16-11-2026
Verified by
JE · SDO, [sub-division]
Maintained by
[Contractor / AMC]
Record integrity
sha256 · 9f2c…a71e
Versions
v1 2024 · v2 2025 · v3 Apr 2026 · v4 Nov 2026
VERIFIED checked in the field ·
AI read by AI, confirmed by a person ·
REGISTER / MAKER from utility or manufacturer records ·
DECLARED stated, not yet verified
Citizen reportsVia QR
This year
3
Last report
Sparking · 02-06-2026
Resolved in
6 h 20 m
Open now
None
End of lifeIndicative
12 of ≈ 25 years used
Copper
≈ [ ] kg
Oil · steel
≈ 260 L · ≈ [ ] kg
Scrap value
At disposal
DocumentsFrom this record
Inspection report
Ready
Failure report
2 on file
Warranty claim pack
Not applicable
RDSS asset export
Ready
Generated by Power Pehchaan · Powered by Chai Kreative and Advisory Private Limited · CIN U74999DL2017PTC314648 · www.chaikreativeadvisory.com · Idea and concept: Kewal Kapoor The utility owns its data. This Patra is generated by the system and is valid only as matched by the live record at the QR. Sample record for illustration; it does not describe a real asset. Power Pehchaan is not a government application.
Photographs capturedEach sealed with time and GPS · tap to open in the live record
Full view16-11-2026
Nameplateread by AI
Oil gaugewithin band
Earthing2 leads
LT boxclosed
Surroundingsvegetation 1 m
Oil and insulationF · every test, its result and who did it
Date
Test or work
Result
By
09/2025
Oil BDV test
38 kV (acceptable)
[Testing agency]
09/2025
Insulation resistance
HV–E [ ] MΩ · LV–E [ ] MΩ
JE, [sub-division]
06/2026
Silica gel
Replaced (pink → blue)
Lineman
11/2026
Oil level and leaks
Level normal · staining at drain valve
Field photo · JE
2017
Oil filtration
Filtered, topped up 20 L
[Contractor]
—
Oil theft incidents
None recorded
—
Generated by Power Pehchaan · Powered by Chai Kreative and Advisory Private Limited · CIN U74999DL2017PTC314648 · www.chaikreativeadvisory.com · Idea and concept: Kewal Kapoor Annexures form part of the Pehchaan Patra and are shown only to authorised utility users. Sample record for illustration; it does not describe a real asset.
ANNEXURE A · 3 / 4
SAMPLE · ILLUSTRATIVE RECORD
PP-UP-SMP-000001-7Full record · पूर्ण रिकॉर्ड
Annexure B · History, people and sources
UTILITY LOGIN ONLY
Failures and repairsG · every failure, in order
Date
Cause
Downtime
Repaired at
Under warranty
Cost
05/2022
LT bushing flashover
9 h
On site
No
₹ [ ]
06/2024
Overload · winding damage
31 h
[Workshop]
No
₹ [ ]
Replacements, upgrades and movesG
Replacement
None · original unit
Capacity upgrade
Recommended: 250 → 400 kVA
Relocation
None
Proposed works
Pre-summer 2027
ResponsibilityH · from the hierarchy
Lineman
[Name] · from roster
Junior Engineer
[Name] · [sub-division]
SDO
[Name] · [sub-division]
Executive Engineer (XEN)
[Name] · [division]
Maintenance contractor
[Contractor]
AMC
[AMC no.] · valid to [ ]
IntelligenceJ · explainable
Risk now
62 / 100 · Watch
Failure risk, next 90 days
18 % (confidence: medium)
Main drivers
Overload days · overdue BDV · failure history
Action 1
Oil BDV test · by 21-11-2026
Action 2
Inspect drain valve; arrest staining
Action 3
Plan 400 kVA before summer 2027
End of life and disposalI
Expected life
≈ 25 years · ≈ 13 remaining
Copper (winding)
≈ [ ] kg
Oil · steel
≈ 260 L · ≈ [ ] kg
Indicative scrap value
At disposal, market rate
Disposal record
Not applicable · in service
Where this record came fromEvery field carries its source and status
Source
System or file
Received
Fields
Status
Utility asset register
[Register / ERP export]
04/2024
Identity, installation, procurement
REGISTER
RDSS GIS survey
[Survey file]
04/2024
Coordinates, network position
VERIFIED
DT meter
[Meter data system]
Daily
Load, energy, loss
METER
Maintenance logs
[Division log]
09/2025
Tests, works
DECLARED
Manufacturer list
[Maker data]
04/2024
Oil, weight, losses
MAKER
Field app
Power Pehchaan
16-11-2026
Photos, nameplate, condition
VERIFIED
Citizen reports
QR · WhatsApp
02-06-2026
Complaints, closure
CITIZEN
Rule: a field is shown as verified only after a field check or an officer’s approval. Everything else shows where it came from, and stays declared or pending until checked.
ApprovalDigital signatures
Verified by (JE)
[Name] · digitally signed 16-11-2026
Approved by (SDO)
[Name] · digitally signed 16-11-2026
Record integrity
sha256 · 9f2c…a71e · v4
Generated by Power Pehchaan · Powered by Chai Kreative and Advisory Private Limited · CIN U74999DL2017PTC314648 · www.chaikreativeadvisory.com · Idea and concept: Kewal Kapoor Annexures form part of the Pehchaan Patra and are shown only to authorised utility users. Sample record for illustration; it does not describe a real asset.